Class in Zendir.Classes | Inherits from Message
Declaration
class FuelFlowMessage;Description
Snapshot of propellant flow along a pump or valve path: transferred mass, instantaneous rate, destination fill fraction, estimated time until full, thermal shutoff, and pressure-limited stall.
Properties
| Declared | Description |
|---|---|
| CurrentRate | Actual mass flow rate through the component [kg/s]. This is the post-leak rate: for acomponent downstream of a leak it reflects the reduced flow that actually reaches it. Tolocate a leak, compare this value between adjacent components |
| EstimatedTimeRemaining | Estimated time until the destination tank reaches capacity at the current rate [s],or positive infinity if there is no net inflow. |
| IsPressureStalled | True when flow is stalled due to insufficient pressure differential across the link. |
| IsThermallyShutoff | True when the destination tank is in thermal shutoff (ingoing flow should be treated as blocked). |
| PercentFull | Fill level of the destination tank as a percentage (0–100). |
| TransferredMass | Cumulative propellant mass moved through this path since the last reset [kg]. |