Declared in FuelValve
Declaration
bool IsBidirectional;Description
When true, the valve allows flow in both directions (inlet to outlet and outlet to inlet). When false (default), the valve operates in directional mode where flow only passes from the inlet port to the outlet port. Bidirectional mode is useful for transfer systems where flow direction depends on tank fill levels or active pumping direction.